163 research outputs found

    Long-term continuous monitoring of the preterm brain with diffuse optical tomography and electroencephalography: A technical note on cap manufacturing

    Get PDF
    open12noDiffuse optical tomography (DOT) has recently proved useful for detecting whole-brain oxygenation changes in preterm and term newborns' brains. The data recording phase in prior explorations was limited up to a maximum of a couple of hours, a time dictated by the need to minimize skin damage caused by the protracted contact with optode holders and interference with concomitant clinical/nursing procedures. In an attempt to extend the data recording phase, we developed a new custom-made cap for multimodal DOT and electroencephalography acquisitions for the neonatal population. The cap was tested on a preterm neonate (28 weeks gestation) for a 7-day continuous monitoring period. The cap was well tolerated by the neonate, who did not suffer any evident discomfort and/or skin damage. Montage and data acquisition using our cap was operated by an attending nurse with no difficulty. DOT data quality was remarkable, with an average of 92% of reliable channels, characterized by the clear presence of the heartbeat in most of them.openopenAlfonso Galderisi; Sabrina Brigadoi; Simone Cutini; Sara Basso Moro; Elisabetta Lolli; Federica Meconi; Silvia Benavides-Varela; Eugenio Baraldi; Piero Amodio; Claudio Cobelli; Daniele Trevisanuto; Roberto Dell'AcquaGalderisi, Alfonso; Brigadoi, Sabrina; Cutini, Simone; BASSO MORO, Sara; Lolli, Elisabetta; Meconi, Federica; Silvia, Benavides-Varela; Baraldi, Eugenio; Amodio, Piero; Cobelli, Claudio; Trevisanuto, Daniele; Dell'Acqua, Robert

    Performances of low level hospital health caregivers after a neonatal resuscitation course

    Get PDF
    Background: High fidelity simulation has been executed to allow the evaluation of technical and non-technical skills of health caregivers. Our objective was to assess technical and non-technical performances of low level hospitals health caregivers who attended a Neonatal Resuscitation course using high fidelity simulation in a standard-setting scenario. Methods: Twenty-three volunteers were asked to manage a simple scenario (infant with secondary apnea) after the course. Technical and non-technical skills were assessed by using previously published scores. Performances were assessed during the scenario and after 2 months by filmed video recordings. Results: Sixteen (69.5%) participants failed to pass the minimum required technical score. Staff experience and participation in previous courses were associated to higher score in technical and non-technical skills, while working in level I or II hospitals did not affect the scores. Previous experience in neonatal resuscitation requiring positive pressure ventilation was associated to better non-technical performance. Technical and non-technical scores were significantly correlated (r = 0.67, p = 0.0005). Delayed and direct evaluation of technical skills provided the same scores. Conclusions: A neonatal resuscitation course, performed by using a high fidelity simulation manikin, had a limited impact on technical and non-technical skills of participants working in low level hospitals. Training programs should be tailored to the participants\u2019 professional background and to the more relevant sessions

    Effect of Maternal Smoking on Breast Milk Interleukin-1α, β-Endorphin, and Leptin Concentrations

    Get PDF
    Tobacco smoke is immunotoxic, but the effect of smoking on the immunologic function of the mammary gland of mothers who smoke cigarettes (“smoker mothers”) has not been studied. Our objective was to test, in smoker mothers, the colostral and transitional milk concentrations of interleukin-(IL)1α. The immunomodulators β-endorphin and leptin were also tested. Pregnant women who self-identified as smokers (≥ 5 cigarettes per day through pregnancy) or nonsmokers were recruited for study participation. The study population included 42 smoker and 40 non-smoker nursing mothers, with otherwise uncomplicated gestation, delivery, and puerperium, who were breast-feeding ad libitum their healthy neonates. Colostrum was obtained on the third postpartum day at 0900 hr and transitional milk on the 10th postpartum day at 0900 hr. IL-1α concentrations were significantly reduced in the colostrum of smoker mothers compared with nonsmoker mothers (p < 0.01). Colostral β-endorphin and leptin concentrations were comparable. No significant differences were found between smoker and nonsmoker lactating mothers in transitional milk concentrations of IL-1α, β-endorphin, and leptin. Moreover, β-endorphin and leptin concentrations were significantly reduced in transitional milk samples compared with colostrum of both smoker and nonsmoker mothers (p < 0.05); also, IL-1α transitional milk concentrations were reduced compared with colostrum, but without any significance. This analysis shows that maternal smoking alters the colostral milk levels of the proinflammatory cytokine IL-1α. The altered postnatal provision of alternative source of the proinflammatory cytokine IL-1α adds understanding to how breast-feeding could be nonprotective against infections among the neonates nursed by smoker mothers

    Neonatal intubation: what are we doing?

    Get PDF
    : How and when the forces are applied during neonatal intubation are currently unknown. This study investigated the pattern of the applied forces by using sensorized laryngoscopes during the intubation process in a neonatal manikin. Nine users of direct laryngoscope and nine users of straight-blade video laryngoscope were included in a neonatal manikin study. During each procedure, relevant forces were measured using a force epiglottis sensor that was placed on the distal surface of the blade. The pattern of the applied forces could be divided into three sections. With the direct laryngoscope, the first section showed either a quick rise of the force or a discontinuous rise with several peaks; after reaching the maximum force, there was a sort of plateau followed by a quick drop of the applied forces. With the video laryngoscope, the first section showed a quick rise of the force; after reaching the maximum force, there was an irregular and heterogeneous plateau, followed by heterogeneous decreases of the applied forces. Moreover, less forces were recorded when using the video laryngoscope.&nbsp; &nbsp; Conclusions: This neonatal manikin study identified three sections in the diagram of the forces applied during intubation, which likely mirrored the three main phases of intubation. Overall, the pattern of each section showed some differences in relation to the laryngoscope (direct or video) that was used during the procedure. These findings may provide useful insights for improving the understanding of the procedure. What is Known: •&nbsp;Neonatal intubation is a life-saving procedure that requires a skilled operator and may cause direct trauma to the&nbsp;tissues and precipitate adverse reactions. • Intubation with a videolaryngoscope requires less force than with a direct laryngoscope, but how and when the&nbsp;forces are applied during the whole neonatal intubation procedure are currently unknown. What is New: • Forces applied to the epiglottis during intubation can be divided into three sections: (i) an initial increase, (ii) a sort&nbsp;of plateau, and (iii) a decrease. • The pattern of each section shows some differences in relation to the laryngoscope (direct or videolaryngoscope)&nbsp;that is used during the procedure

    Applied forces with direct versus indirect laryngoscopy in neonatal intubation: a randomized crossover mannequin study

    Get PDF
    Purpose: In adult mannequins, videolaryngoscopy improves glottic visualization with lower force applied to upper airway tissues and reduced task workload compared with direct laryngoscopy. This trial compared oropharyngeal applied forces and subjective workload during direct vs indirect (video) laryngoscopy in a neonatal mannequin. Methods: We conducted a randomized crossover trial of intubation with direct laryngoscopy, straight blade videolaryngoscopy, and hyperangulated videolaryngoscopy in a neonatal mannequin. Thirty neonatal/pediatric/anesthesiology consultants and residents participated. The primary outcome measure was the maximum peak force applied during intubation. Secondary outcome measures included the average peak force applied during intubation, time needed to intubate, and subjective workload. Results: Direct laryngoscopy median forces on the epiglottis were 8.2 N maximum peak and 6.8 N average peak. Straight blade videolaryngoscopy median forces were 4.7 N maximum peak and 3.6 N average peak. Hyperangulated videolaryngoscopy median forces were 2.8 N maximum peak and 2.1 N average peak. The differences were significant between direct laryngoscopy and straight blade videolaryngoscopy, and between direct laryngoscopy and hyperangulated videolaryngoscopy. Significant differences were also found in the top 10th percentile forces on the epiglottis and palate, but not in the median forces on the palate. Time to intubation and subjective workload were comparable with videolaryngoscopy vs direct laryngoscopy. Conclusions: The lower force applied during videolaryngoscopy in a neonatal mannequin model suggests a possible benefit in reducing potential patient harm during intubation, but the clinical implications require assessment in future studies. Registration: ClinicalTrials.gov (NCT05197868); registered 20 January 2022

    Outcome of infants with 10 min Apgar scores of 0-1 in a low-resource setting

    Get PDF
    Background In high-resource settings, postponing the interruption of cardiopulmonary resuscitation from 10 to 20 min after birth has been recently suggested, but data from low-resource settings are lacking. We investigated the outcome of newborns with Apgar scores of 0–1 at 10 min of resuscitative efforts in a low-resource setting. Methods This observational substudy from the NeoSupra trial included all 49 late preterm/full-term newborns with Apgar scores of 0–1 at 10 min of resuscitation. The study was carried out at Mulago National Referral Hospital (Kampala, Uganda) between May 2018 and August 2019. Outcome measures were mortality and hypoxic-ischaemic encephalopathy in the first week of life. All resuscitations were video recorded and daily reviewed by trial researchers. Results Median duration of resuscitation was 32 min (IQR 17–37). Advanced resuscitation was provided to 21/49 neonates (43%). Overall, 48 neonates (98%) died within 2 days of life (44 in the delivery room, three on the first day and one on the second day) and one survived at 1 week with severe hypoxic-ischaemic encephalopathy. Conclusion Our study adds information from a low-resource setting to the recent evidence from high-resource settings about prolonging the resuscitation in infants with Apgar scores of 0–1 at 10 min. The vast majority died in the delivery room despite prolonged resuscitative efforts. We confirm that duration of resuscitation should be tailored to the setting, while the focus in low-resource settings should be improving the quality of antenatal and immediately after birth care.acceptedVersio

    Neonatal resuscitation using a supraglottic airway device for improved mortality and morbidity outcomes in a low-income country: Study protocol for a randomized trial.

    Get PDF
    Background Intrapartum-related death is the third leading cause of under-5 mortality. Effective ventilation during neonatal resuscitation has the potential to reduce 40% of these deaths. Face-mask ventilation performed by midwives is globally the most common method of resuscitating neonates. It requires considerable operator skills and continuous training because of its complexity. The i-gel® is a cuffless supraglottic airway which is easy to insert and provides an efficient seal that prevents air leakage; it has the potential to enhance performance in neonatal resuscitation. A pilot study in Uganda demonstrated that midwives could safely resuscitate newborns with the i-gel® after a short training session. The aim of the present trial is to investigate whether the use of a cuffless supraglottic airway device compared with face-mask ventilation during neonatal resuscitation can reduce mortality and morbidity in asphyxiated neonates. Methods A randomized phase III open-label superiority controlled clinical trial will be conducted at Mulago Hospital, Kampala, Uganda, in asphyxiated neonates in the delivery units. Prior to the intervention, health staff performing resuscitation will receive training in accordance with the Helping Babies Breathe curriculum with a special module for training on supraglottic airway insertion. A total of 1150 to 1240 babies (depending on cluster size) that need positive pressure ventilation and that have an expected gestational age of more than 34 weeks and an expected birth weight of more than 2000 g will be ventilated by daily unmasked randomization with a supraglottic airway device (i-gel®) (intervention group) or with a face mask (control group). The primary outcome will be a composite outcome of 7-day mortality and admission to neonatal intensive care unit (NICU) with neonatal encephalopathy. Discussion Although indications for the beneficial effect of a supraglottic airway device in the context of neonatal resuscitation exist, so far no large studies powered to assess mortality and morbidity have been carried out. We hypothesize that effective ventilation will be easier to achieve with a supraglottic airway device than with a face mask, decreasing early neonatal mortality and brain injury from neonatal encephalopathy. The findings of this trial will be important for low and middle-resource settings where the majority of intrapartum-related events occur.publishedVersio
    • …
    corecore